Franklin Electric | Grid Solutions
  • News
  • About
  • Affiliations
  • Corporate
  • Global
  • Contact
  • Standby Battery Testers
    • CELLTRON Advantage
      • Features
      • Specs
      • Literature
      • Accessories
      • Updates
    • CELLTRON Ultra
      • Features
      • Specifications
      • Literature
      • Accessories
      • Updates
    • CELLTRON Genstart
      • Features
      • Specifications
      • Literature
      • Accessories
    • CELLTRON SCP 6/12
      • Features
      • Specifications
      • Literature
    • LEGACY Battery Testers
      • Features
      • Literature
  • Standby Battery Monitors
    • CELLGUARD BMS Estimator
    • CELLGUARD System-GEN-3
      • Features
      • Specifications
      • Literature
    • CELLGUARD System-GEN-2
      • Features
      • Specifications
      • Literature
    • CELLGUARD System-ELS+ Electrolyte Level Monitor
      • Features
      • Specs: Sensor
      • Specs: Alarm Hub
      • Literature
    • Data Management Software
      • Celltraq
      • Batterynet
  • Utility Grid Monitoring
    • INCON Optimizer 3
      • Features
      • Specs
      • Literature
      • Accessories
      • Updates
    • INCON 1250 LTC
      • Features
      • Specs
      • Literature
      • Accessories
    • INCON 1250B
      • Features
      • Specs
      • Literature
      • Accessories
    • INCON 1511 LTC
      • Features
      • Specs
      • Literature
      • Accessories
    • GRIDSENSE Line IQ
      • Features
      • Specs
      • Literature
      • Accessories
  • Industries
    • Telecommunications
    • Power Utilities
      • NERC PRC-005
    • Data Centers
    • Industrial Critical Power
      • NFPA-110 Requirements
  • Sales, Support & Ref Values
    • Battery Reference Values
    • Distributors
    • Product Updates
    • Customer Service & Repair
    • Training Videos
    • Ask Us A Question
    • Technical Papers
  • News
  • About
  • Affiliations
  • Corporate
  • Global
  • Contact
  • Request a Quote
  • Standby Battery Testers
    • CELLTRON Advantage
      • Features
      • Specs
      • Literature
      • Accessories
      • Updates
    • CELLTRON Ultra
      • Features
      • Specifications
      • Literature
      • Accessories
      • Updates
    • CELLTRON Genstart
      • Features
      • Specifications
      • Literature
      • Accessories
    • CELLTRON SCP 6/12
      • Features
      • Specifications
      • Literature
    • LEGACY Battery Testers
      • Features
      • Literature
  • Standby Battery Monitors
    • CELLGUARD BMS Estimator
    • CELLGUARD System-GEN-3
      • Features
      • Specifications
      • Literature
    • CELLGUARD System-GEN-2
      • Features
      • Specifications
      • Literature
    • CELLGUARD System-ELS+ Electrolyte Level Monitor
      • Features
      • Specs: Sensor
      • Specs: Alarm Hub
      • Literature
    • Data Management Software
      • Celltraq
      • Batterynet
  • Utility Grid Monitoring
    • INCON Optimizer 3
      • Features
      • Specs
      • Literature
      • Accessories
      • Updates
    • INCON 1250 LTC
      • Features
      • Specs
      • Literature
      • Accessories
    • INCON 1250B
      • Features
      • Specs
      • Literature
      • Accessories
    • INCON 1511 LTC
      • Features
      • Specs
      • Literature
      • Accessories
    • GRIDSENSE Line IQ
      • Features
      • Specs
      • Literature
      • Accessories
  • Industries
    • Telecommunications
    • Power Utilities
      • NERC PRC-005
    • Data Centers
    • Industrial Critical Power
      • NFPA-110 Requirements
  • Sales, Support & Ref Values
    • Battery Reference Values
    • Distributors
    • Product Updates
    • Customer Service & Repair
    • Training Videos
    • Ask Us A Question
    • Technical Papers
Back To Standby Battery Testers

CELLTRON Advantage

  • Features
  • Specs
  • Literature
  • Accessories
  • Updates
  • Request Quote

SERVICE BULLETIN

Effective 1/1/2019 our service department will no longer be able to repair or calibrate handheld tester units produced prior to 1/1/2012.  

The first 4 digits of our S/N are MMYY of manufacture date; 
0707123456 is from July of 2007 
1208123456 is from December of 2008

All units with 6 digit serial numbers would have been produced prior to 2005 and are no longer eligible for service.
For replacement/trade in options and details please
Contact Your Regional Manager

For questions/concerns please
Contact Franklin Electric Customer Service
1-844-344-5025

Current Versions

REV H Posted 6/13/18

Updates Include
Ehancements:
  • Added ability to scan/display battery temperature
  • Added ability to edit battery temperature
  • Enhanced Temperature capture test flow for each battery
  • Added 18V battery testing capability
  • Added warning buzzer when measured values are outside set thresholds
  • Added warning buzzer when measured conductance is zero
  • Added German language updates
  • Added display of Vinculum Firmware to version screen
Bug Fixes:
  • Corrected import function to allow import of CDI files containing small system hierarchies
  • Corrected USB initialization message displayed during Export/Import
  • Corrected export function for a selection of one string
  • Corrected display of strap resistance value when value is greater than 999µΩ
  • Corrected internal battery pack voltage thresholds to denote low internal battery prior to conductance testing and during power on.
  • Corrected numeric scrolling function
  • Corrected DMM DC voltage threshold for over voltage
  • Corrected Expansion Module display

CAD 5000 REV. H
CPU FW: 192-320246H
DSP FW: 192-320247F
EEPROM: 192-330385G
FLASH: 192-350311H

CAD 5200 REV. H
CPU FW: 192-320246H
DSP FW: 192-320247F
EEPROM: 192-330386G
FLASH: 192-350311H

CAD 5500 REV. H
CPU FW: 192-320246H
DSP FW: 192-320247F
EEPROM: 192-330387G
FLASH: 192-350311H

Celltron Advantage Applications

Tester Interface App. Ver. 8.5.0.4   Posted 2/14/17

USB Driver for Windows 7/8.1  Posted 11/7/17

USB Driver for Windows 10  Posted 6/13/18


Register or Login for Product Updates

Product Updates 
  • Battery Reference Values
  • Product Updates
  • Distributors
  • Ask Us A Question
  • Blog
  • Contact
  • Privacy Policy
  • Terms of Use
  • Power Utilities
  • NERC PRC-005
  • Telecommunications
  • NFPA-110 Requirements
  • Data Centers
  • LinkedIn
  • Twitter
  • YouTube
Sign up for our email newsletter

Sign up for our e-newsletter for news and updates

© 2019 Franklin Electric|
  • Client Login |
  • Search |
  • ISO 9001 Registered Company