Optimizer3-Cabinet-Wide.psd


OPTIMIZER3 CABINET

The Optimizer3 pre-assembled cabinet offers a turnkey comprehensive circuit breaker monitoring solution for rapid deployment. With configurable options available to suit specific application and monitoring needs, the Optimizer3 cabinet comes with all components, sensors, and accessories pre-mounted, pre-wired, and factory tested for streamlined installation.

 

Rugged, 16 gauge steel construction enclosure


IP66 / NEMA 4 ingress protection against water, oil, dust


Sensor inputs pre-wired to test-disconnect terminal blocks


Integrated circuit breakers for AC / DC power sources


Internal cabinet heater prevents condensation

Built-in hooded cabinet vents allow for proper air flow


All components pre-wired and factory tested


Eliminates on-site drilling or tapping to mount devices


Customize to include cabinet / tank heater monitoring and trip coil isolation

INTEGRATED COMPONENTS

All Optimizer3 Cabinets come with these factory-installed components.

 

Optimizer3 - Cabinet - Accessory - AC Circuit Breakers.psd

Circuit Breakers

The cabinet is equipped with integrated circuit breakers designed to manage both AC and DC power sources.

Integrated circuit breakers ensure that both AC and DC circuits are protected from overloads, short circuits, and faults, minimizing the risk of electrical fires and damage to equipment.

Optimizer3 - Cabinet - Accessory - Terminal Blocks.psd

Terminal Blocks

Pre-wired terminal blocks reduce installation time and eliminate potential wiring errors, enhancing overall reliability and efficiency of the system.

These terminal blocks simplify testing and maintenance by allowing for quick and safe disconnection of sensors without interrupting the entire system. This design enables technicians to easily perform diagnostics, calibrations, and troubleshooting, ensuring minimal downtime.

Optimizer3 - Cabinet - Accessory - Cabinet Heater.psd

Cabinet Heater

In environments with fluctuating or low temperatures, condensation can form inside the cabinet, leading to moisture accumulation and potential damage to electrical components.

The integrated heater maintains a consistent internal temperature, protecting sensitive electronics from humidity and temperature-related stress, ensuring reliable operation, and reducing the risk of corrosion and electrical faults.

OPTIONAL ACCESSORIES

Optimizer3 Cabinets can be orderd with these optional factory-installed components.

 

OM3 TSM - Accesory.psd

Trip Signature Monitoring

The INCON® Optimizer3 Trip Signature Monitor provides high-fidelity trip coil signature analysis for an unprecedented level of insight into circuit breaker performance. Proprietary TripTracer™ technology captures the waveform signature of each trip and close operation and compares it to a baseline to detect potential circuit breaker deficiencies and enable proactive maintenance actions.

Optimizer3 - Accessory - AC Current Transducer.psd

AC Current Transducer

Most breakers have continuously-running cabinet heaters to prevent moisture condensation by keeping the control cabinet warmer than the outside air. These heaters typically use AC power and can be monitored using an AC Current Transducer.

Once the heater’s nominal current is determined, the Optimizer3 can be programmed to alarm if a heater fails, resulting in a current drop.

Optimizer3 - Cabinet - Accessory - Tank Heater Monitor.psd

Power Status Monitor

Tank heaters are thermostatically controlled, so they do not run continuously. The Power Status Monitor is wired into the heater supply circuit and enables the current draw of the heaters to be monitored only when they are turned on.

If one or more of the heater elements fails, the current draw will be too low and the Optimizer3 will trigger a heater alarm.

Optimizer3 - Accessory - Trip Coil Isolator.psd

Trip Coil Isolator

The Trip Coil Isolator is a cost effective means to achieve compliance with regulations requiring redundant trip circuits on all circuit breakers 115 KV and above as well as physical isolation of critical circuits in medium and high voltage environments.

With the Trip Coil Isolator, the Optimizer3 can monitor trip circuits 1 & 2 as if it was hard-wired to them both, yet maintain the isolation required by regulations.

Optimizer Hero.psd

INCON® OPTIMIZER3 CIRCUIT BREAKER MONITOR

The INCON® Optimizer3 Circuit Breaker Monitor is an online continuous performance monitor for high voltage circuit breakers, designed to facilitate condition-based maintenance with real-time performance and health data.

With early detection of circuit breaker deficiencies, the Optimizer3 enables utilities to proactively address issues before they escalate, saving both time and resources while helping to boost reliability. Deploy maintenance with intelligence, defer offline testing, limit truck rolls, and lower overall maintenance costs with the Optimizer3

Extend Circuit Breaker Life

Defer or Eliminate Offline Testing

Employ Condition-Based Maintenance

 

 

LEARN MORE ABOUT OPTIMIZER3